SDS2100 User Guide
characters, it is sent immediately, along with any awaiting characters, to the TCP
connection. This minimizes the response time for specific protocol characters on the
serial line (for example, ETX, EOT, etc.). Setting the first sendchar to 00 disables the
recognition of the characters. Alternatively, the two characters can be interpreted as
a sequence (see

Telnet Terminal Type

This parameter appears only if the terminal type option is enabled in Disconnect
Mode (see
name for the Telnet terminal type. Enter only one name.
If the terminal type option is enabled, the unit also reacts to the EOR (end of record)
and binary options, which can be used for applications like terminal emulation to IBM
hosts.

Channel (Port) Password

This parameter appears only if the channel (port) password option is enabled in
Disconnect Mode (see above). If it is enabled, you can set a password on the serial
port.

Expert Settings

Note:
You can change these settings via Telnet or serial connections only, not on
the WEB-Manager.
Pack Control
above).
DisConnMode
above). If this option is enabled, you can use the terminal
Figure 3-12. Expert Settings Options
40
3: Configuring the Unit