C o n f i g u r i n g t h e P a r t n e r P r i n t e r
The partner printer must be configured to 115200 Baud, No parity,
8-bit word length, 1 stop bit, and XON/XOFF flow control.
Select Setup, Port Settings, Serial Comm from the partner printer's
1.
Main Menu. If password protection in enabled, press Feed/Cut three
times, then press Enter/Pause before you see the Setup Menu
options.
Select Baud Rate and press
2.
Press Enter/Pause.
Press
or
3.
Press Enter/Pause.
Press
or
4.
Press Enter/Pause.
Press
or
5.
Press Enter/Pause.
Press
or
6.
XOFF. Press Enter/Pause.
U s i n g t h e S m a r t R e l a y T e l n e t C o m m a n d s
See the following list of commands to configure the printers.
SET PRN RELay PORt [None/S2]
Sets the Smart Relay Partner Identification (port) number to None (no partner
printer) or S2 (partner printer connected to serial port 2). The default is None.
to select Word Length. Scroll until you see 8.
to select Stop Bits. Scroll until you see 1.
to select Parity. Scroll until you see None.
to select Flow Control. Scroll until you see XON-
or
to scroll until you see 115200.
Using the Smart Relay System 5-5