Qlogic SANbox 5000 Series Interface Manual page 272

Fibre channel switch
Hide thumbs Also See for SANbox 5000 Series:
Table of Contents

Advertisement

13 – Command Reference
Show Switch
PrincipalSwitchRole
BoardTemp (1) - Degrees Celsius
SwitchDiagnosticsStatus
SwitchTemperatureStatus
Examples
The following is an example of the Show Switch command:
SANbox #> show switch
Switch Information
------------------
SymbolicName
SwitchWWN
BootVersion
CreditPool
DomainID
FirstPortAddress
FlashSize - MBytes
LogFilterLevel
MaxPorts
NumberOfSwitchResets
ReasonForLastReset
ActiveImageVersion - build date
PendingImageVersion - build date
ActiveConfiguration
AdminState
AdminModeActive
Beacon
OperationalState
PrincipalSwitchRole
BoardTemp (1) - Degrees Celsius
SwitchDiagnosticsStatus
SwitchTemperatureStatus
13-142
Table 13-27. Switch Operational Parameters (Continued)
Parameter
Description
Principal switch status. True indicates that this
switch is the principal switch.
Internal switch temperature at circuit board sensor
1.
Results of the power-on self test
Switch temperature status: normal, warning, fail-
ure.
SANbox
10:00:00:c0:dd:00:bc:56
Vx.x.x.x-0 (day month date time year)
0
19 (0x13)
130000
128
Critical
20
15
PowerUp
Vx.x.x.0 (day month date time year)
Vx.x.x.0 (day month date time year)
default
Online
False
Off
Online
False
32
Passed
Normal
S
59183-01 A

Advertisement

Table of Contents
loading

Table of Contents