System Setup - Digital Watchdog x12 WDR PTZ User Manual

X12 analog wdr ptz in/outdoor camera
Table of Contents

Advertisement

OSD -

SYSTEM SETUP

5
SET HOME POSITION
- - - - - - - - - - - - - - - - - - - - - - - - - - -
MOVE TO TARGET POSITION
[NEAR:SELECT/FAR:CANCEL]
6
SET NORTH DIRECTION
- - - - - - - - - - - - - - - - - - - - - - - - - - -
MOVE TO TARGET POSITION
[NEAR:SELECT/FAR:CANCEL]
7
FAN HEATER SETUP
- - - - - - - - - - - - - - - - - - - - - - - - - - -
FAN RUN TEMP
HEATER RUN TEMP
BACK
EXIT
0/0/x1/E
0/0/x1/N
25 C
5 C
5
SET HOME POSITION
Home position means the origin of pan angle calculation.
The value of pan angle displayed on the screen is based on this
home position. Home is not effective to tilt angle.
By using joystick, move the camera to the desired position and
press near key.
If you change the location of the home position, all horizontal
location of functions such as preset, scan, pattern, group and
privacy zone mask will be shifted based on the changed home
position.
If there are no setup for those functions like preset, pattern,
scan, group camera will automatically move to home position
after rebooting.
If power up action is set to be on, camera will continue the
function which is executed lastly after rebooting.
Set Home Position?
When you replace the camera block or the orientation of camera is
changed due to maintenance operations, it is very difficult to maintain
the same pan orientation. Therefore, all function data maintain on
pan orientation such as preset, scan, pattern, group and privacy zone
mask are not useful any more accordingly.
However, even in this case, you can reuse the data if you redefine set
home position on the previous home position.
SET NORTH DIRECTION
6
By using joystick, move the camera to the desired north
position and press enter (near/save).
The direction will be displayed in the screen
[NEAR:SELECT/FAR:CANCEL]
Direction will be displayed from:
N(North) / S(South) / E(East) / W(West) / NE(Northeast) /
NW(Northwest) / SE(Southeast) / SW(Southwest).
FAN HEATER SETUP
7
Sets the fan/heater enabled/disabled according to the
temperature.
This menu will be displayed only for fan/heater model.
FAN RUN TEMP
Above this temperature, the blower fan will start automatically.
HEATER RUN TEMP
Below this temperature, the heater will be tuned on automatically.
38