Interval
FirmwareURL
DnsLookupType
DnsSrvPrefix
Username
Password
ITSP Provisioning
Method
When Method is set to Periodically, this is the number of
seconds between each checking of f/w upgrade check from
FirmwareURL. If value is 0, device checks once only on
system start (i.e., equivalent to setting Method to System
Start)
URL of firmware package. URL must include scheme.
Supported schemes are http:// and tftp://
Control what type of DNS record to lookup. Available choices
are:
-
A Record Only
-
SRV Record Only
-
- Try Both
Note: Option not available on OBi100/OBi110
Control whether to add a standard prefix to the domain
name when looking up a SRV Record. For HTTP and HTTPS,
the prefix to add is "_http._tcp.". For TFTP, the prefix to add
is "_tfto._udp."
Available choices are:
-
No Prefix
-
With Prefix
-
Try Both
Note: Option not available on OBi100/OBi110
Username for authentication, if needed, if scheme is http://
Password for authentication, if needed, if scheme is http://
Current operational method of Provisioning. Available
choices are:
-
Disabled = Do not download from ConfigURL
-
System Start = Download from ConfigURL just once
on system start
-
Periodically = Download from ConfigURL on system
start, and then periodically at the interval specified
in the Interval paramter
Note: First download on system start will be performed after
a random delay of 30 – 90s. If there is a firmware update
scheduled at the beginning. Or a random delay of 10- 70s..
Copyright 2010-2013 Obihai Technology, Inc.
0
A Record Only
No Prefix
System Start