Installing the Ozone Filter, Photoconductor,
Toner Casselte and Cleaning Pad
INSTALLATION
Installing the Ozone Filter, Photoconductor,
Toner Cassette and Cleaning Pad
Before using the machine, install the photoconductor,
toner cassette and the
cleaning pad as in the following procedure:
n
El
El
Remove all pieces of tape at-
tached to the machine. Lift the up-
per unit release lever and open
the upper unit by sliding it to the
right.
Caution: When opening the up-
per unit, make sure nobody
nearby injures themselves
on it.
Insert the ozone filter holding the
tip in the slot at the back left of
the machine.
Note: The tip should point up-
ward.
Handle the ozone filter carefully.
If you drop the ozone filter, it may
break.
With the black protective sheet
still attached, fit the photoconduc-
tor into the two slots as shown.
One end of the photoconductor
is
marked "R". This should be at the
front of the machine as shown.
c!
,
Remove the black sheet.
Caution:
Never touch the photo-
conductor (green drum).