Agency Approvals And Listings - Zeta Classic 2000 MKII Installation And Operation Manual

January 2002,part # z6000-0001 man-z3k-01 revision 1.0
Table of Contents

Advertisement

Zeta Alarm Systems.
1 . 3
A g e n c y A p p r o v a l s a n d L i s t i n g s
The Classic 2000 Mk II Control System is designed to comply with Underwriter Laboratories (UL) Stan-
dard 864, Control Units for Fire-Protective Signaling Systems.
The Classic 2000 Mk II are Underwriters Laboratories listed for the applications described below:
Type
Local
Central Station
Remote Station
*Automatic (A), Manual (M), Water Flow (WF), Sprinkler Supervisory (SS)
**March Time (M), Coded (C), Non Coded (NC), Digital Alarm Communicator (DACT)- separately listed
Anyone installing this system should have familiarity with:
Installation Manual Part # 3000-6000
NFPA 72
NEC Article 300 Wiring Methods
NEC 760 Fire Protective Signaling Systems
EIA-485 and EIA-232 Serial Interface Standards
Applicable Local and State Building Codes
Requirements of Local Authority Having Jurisdiction
Underwriters Laboratories has the following Pre-connection Requirements:
A
All AC wiring connected to the Classic 2000 Mk II enclosure is to be installed in conduit
B
All field wiring must be installed in accordance with the National Electric Code (NFPA 70)
C
All field wiring must be 18 AWG or larger (system accommodates 14-24 AWG)
D
High and Low voltage wiring should be segregated and routed as described in Section 1.4.8.1
E
Use only the compatible sensors and modules listed in Appendix C-2 on the SLC loops
F
The Control mounting location should allow easy access and proximity to all audible alerts
and local annunciation by the person(s) having responsibility for maintaining and supervising
the system
G
All 2-wire smoke detectors utilized on ZTZB/ZFZA must be listed as compatible in Appendix C
H
Supervised audible and visual appliances as listed in Appendix C Compatible Devices should
be located so as to conform to UL and the ADA where required
I
A full system checkout must be performed any time the panel is programmed
J
The system should be maintained in accordance with NFPA 72 standards
Specific instructions on configuring and programming to achieve some common
applications are contained in Section 5, and may have additional requirements.
Please remember that all installations are regulated by the Local or State
Authority Having Jurisdiction (AHJ) as they interpret the applicable
Revision 1.0
* Type Service
A, M, WF, SS
A, M, WF, SS
A, M, WF, SS
NEC, NFPA and UL standards and regulations.
Part # MAN-Z3K-01
Classic 2000 Mk II Operation Manual
** Type Signaling
M, NC or C
DACT
DACT, REV. POL.
Models
3002-3008
3002-3008
3002-3008
Page 6