Voice Commands; Configuration Commands; Fclass=8 - Select Voice Mode; Fclass=80 - Select Voiceview Mode - Conexant H08-15355F Reference Manual

Commands for host-processed and host-controlled modems
Table of Contents

Advertisement

5.2 Voice Commands

5.2.1 Configuration Commands

5.2.1.1 +FCLASS=8 - Select Voice Mode

+FCLASS=8 selects the Voice Mode. The Voice Mode commands and responses described in this section are applicable
when command +FCLASS=8. (See Section 3.2.1.2 for the definition of the FCLASS command.)

5.2.1.2 +FCLASS=80 - Select VoiceView Mode

+FCLASS=80 selects the VoiceView Mode. The Voice Mode commands and responses described in this section are
applicable when command +FCLASS=80. (See Section 3.2.1.2 for the definition of the FCLASS command.)

5.2.1.3 +VNH - Automatic Hang-up Control

This command enables or disables automatic hangups.
Syntax
+VNH=<hook>
Defined Values
<hook>
Decimal number corresponding to the selected option.
Reporting Current or Selected Values
Command:
+VNH?
Response:
+VNH: <hook>
Example:
+VNH: 0
Reporting Supported Range of Parameter Values
Command:
+VNH=?
Response:
+VNH: (<hook> range)
Example:
+VNH: (0-2)
Result Codes
OK
<hook> = 0-2.
ERROR
Otherwise.
5-4
Command Reference Manual
0
The modem enables automatic hangups as is normal in other modes.
1
The modem disables automatic hangups usually found in the other non-Voice Modes.
2
The modem disables automatic hangups in the other non-Voice Modes. The modem
performs only a "logical" hangup (returns to OK result code).
For the default setting.