K - Flow Control; M - Asynchronous/Synchronous Mode Selection; Q - Sync/Async Mode - Conexant H08-15355F Reference Manual

Commands for host-processed and host-controlled modems
Table of Contents

Advertisement

3.2.2.8 &K - Flow Control
This command defines the DTE/DCE (terminal/modem) flow control mechanism.
Syntax
&K[<value>]
Defined Values
<value>
Decimal number corresponding to the selected option.
Result Codes
OK
ERROR
3.2.2.9 &M - Asynchronous/Synchronous Mode Selection
This command is included for compatibility only and has no effect other than returning a result code. The only valid values
are 0-3.
Syntax
&M[<mode>]
Defined Values
<mode >
Decimal number corresponding to the selected value: 0-3.
Result Codes
OK
ERROR
3.2.2.10 &Q - Sync/Async Mode
This command determines the DTR operating mode. (Also, see \N.)
NOTE: When the &Q0 is issued to select the mode, the subsequent connect message will report the DCE speed regardless
of the W command and S95 settings.
Syntax
&Q[<mode>]
Defined Values
<mode >
Decimal number corresponding to the selected mode:
Result Codes
3-14
Command Reference Manual
0
Disables flow control.
3
Enables RTS/CTS flow control. (Default for data modem modes.)
4
Enables XON/XOFF flow control.
5
Included for compatibility only and has no effect other than returning an OK result code.
6
Included for compatibility only and has no effect other than returning an OK result code.
<value> = 0, 3, 4, 5, or 6.
Otherwise.
<mode> = 0 to 3.
Otherwise.
0
Selects asynchronous operation in normal mode (speed buffering)
1
Selects asynchronous operation in normal mode (speed buffering)
2
Selects asynchronous operation in normal mode (speed buffering)
3
Selects asynchronous operation in normal mode (speed buffering)
5
Selects asynchronous operation in error correction mode
6
Selects asynchronous operation in normal mode (speed buffering).
OK
<mode > = 0-3, 5, 6.
ERROR Otherwise.