Sony PDW-HR1 Operation Manual page 146

Professional disc field station
Hide thumbs Also See for PDW-HR1:
Table of Contents

Advertisement

Menu items in the 600s, relating to the timecode, metadata, and UMID (TIME CODE GENERATOR/META DATA)
Item number Item name
607
U-BIT BINARY GROUP FLAG
611
TC OUTPUT PHASE IN EE MODE
612
TC OUTPUT MUTING IN SEARCH
MODE
618
UPCONV EMBEDDED VITC
619
VITC
634
WATCH AUTO ADJUST
651
UMID SDI OUTPUT
652
UMID SD VANC LINE
146
Setup Menu
Settings
Select the user bits to be used in the timecode generated by the
timecode generator.
000 (000:not specified): Character set not specified.
001 (001:iso character): 8-bit characters compliant with ISO 646 and
ISO 2022.
010 (010:unassigned-1): Undefined.
011 (011:unassigned-2): Undefined.
100 (100:unassigned-3): Undefined.
101 (101:page / line): SMPTE-262M page/line multiplex system.
110 (110:unassigned-4): Undefined.
111 (111:unassigned-5): Undefined.
Select the timecode output mode for output from the TIME CODE OUT
connector in E-E mode.
thru (through): Output the timecode input to the TIME CODE IN
connector as it is.
v-in (video input phase): Output the timecode with the same phase as
the input video signal phase.
v-out (video output phase): Output the timecode with the same phase
as the output video signal phase.
Select whether to suppress the output from the TIME CODE OUT
connector in jog/shuttle mode.
on: Suppress.
off: Do not suppress.
Select the source of the VITC embedded into output HDSDI when up
converting during playback of SD discs.
VITC: Select the VITC of the SD disc.
LTC: Select the LTC of the SD disc.
Select whether to record VITC signals generated by the internal
timecode generator. This setting applies when the recording format is SD
and a VITC signal is present in the input video signal and the line of that
VITC signal is set to "thru" in setup menu item 723.
off: Record the detected VITC on the lowest numbered line that has
been set to "thru".
on: When VITC is detected on a line that has been set to "thru", and the
number of that line is lower than the numbers of the lines selected
with setup menu items 601 and 602, record the VITC of that line.
When VITC is detected on a line that has been set to "thru", and the
number of that line is higher than the numbers of the lines selected
with setup menu items 601 and 602, record internally generated
VITC.
Select whether to adjust the unit's internal clock to time data embedded
in user bits, when time data is embedded in the LTC user bits input to the
TIME CODE IN connector.
off: Do not adjust the time.
on: Adjust the time.
Select whether to output UMID in the VANC of the SDI output.
off: Do not output.
on: Output.
See "Using UMID Data" (page 184) for more information about UMID.
Select the line in which UMID is output when menu item 651 is set to
"on".
12 H (12 line), 13 H (13 line), 15 H (15 line), 16 H (16 line), 17 H (17
line), 18 H (18 line), 19 H (19 line) (59.94i/59.94P/29.97P mode)
9 H (9 line), 10 H (10 line), 12 H (12 line), 13 H (13 line), 14 H (14 line),
15 H (15 line), 16 H (16 line), 17 H (17 line), 18 H (18 line) (50i/50P/25P
mode)
See "Using UMID Data" (page 184) for more information about UMID.

Advertisement

Table of Contents
loading

Table of Contents