Operating On Files; Exiting File Operations; For Windows - Sony PDW-HR1 Operation Manual

Professional disc field station
Hide thumbs Also See for PDW-HR1:
Table of Contents

Advertisement

Operating on files

1
Start Explorer.
Check that a drive letter has been assigned to this unit.
(The drive letter will differ depending on the number
of other peripherals connected to the remote
computer.)
2
Use Explorer to perform file operations on the disc
loaded in this unit.
You can operate in the same way that you operate on
local drives and files on network computers.
Notes
• If you power this unit off during an FAM
connection, the data transferred thus far is discarded.
• All file operations are not possible for some types of
files.
For details, see "File operation restrictions"
(page 117).
To eject discs from a remote computer
Right click the icon representing this unit in Explorer, and
select "Eject" from the menu which appears.

Exiting file operations

For Windows XP or Windows Vista
Note
Do not disconnect the cable before performing steps 1 to 3.
1
Do one of the following on the
displayed in the remote computer's taskbar.
• Double click.
• Right click, and select the "Safely Remove
Hardware".
The "Safely Remove Hardware" dialog appears.
2
Select "Sony XDCAM PDW-HR1 IEEE 1394 SBP2
Device" and click "Stop".
The "Stop a Hardware device" dialog appears.
3
Select "Sony XDCAM PDW-HR1 IEEE 1394 SBP2
Device" and click "OK".
• Windows XP: "Sony XDCAM PDW-HR1 IEEE
1394 SBP2 Device" is deleted from the "Hardware
devices" list.
124
File Operations in File Access Mode (for Windows)
• Windows Vista: A message appears to inform you
This unit can now resume normal operations. (The
limitations described in "Operation limitations during
FAM connections" no longer apply.)
4
Press the PC REMOTE button, turning it off. (This
disables remote access (see page 16).)

For Windows 7

Note
Do not disconnect the cable before performing step 1.
1
Click the
taskbar, and then click "Eject Solid state disk".
"The 'Sony XDCAM PDW-HR1 IEEE 1394 SBP2
Device' device can now be safely removed from the
computer" appears.
This unit can now resume normal operations. (The
limitations described in "Operation limitations during
FAM connections" no longer apply.)
2
Disconnect the i.LINK cable as required.
To reconnect
Press the PC REMOTE button, lighting it.
This makes it possible to access this unit from a computer.
or
icon
that you can now safely remove the device from
your computer.
icon displayed in the remote computer's

Advertisement

Table of Contents
loading

Table of Contents