Thermal Management Specifications
Figure 6-1.
TTV Thermal Profile
Notes:
1.
Refer to
2.
Refer to the
Table 6-2.
130W TTV Thermal Profile (Sheet 1 of 2)
Power (W)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
Thermal/Mechanical Specifications and Design Guide
Table 6-2
for discrete points that constitute thermal profile.
Chapter 8
for system and environmental implementation details.
Maximum TTV
T
( C)
CASE
43.4
43.8
44.1
44.5
44.8
45.2
45.6
45.9
46.3
46.6
47.0
47.4
47.7
48.1
48.4
48.8
49.2
49.5
Power (W)
Maximum TTV
T
CASE
66
55.3
68
55.6
70
56.0
72
56.4
73
56.5
76
57.1
78
57.4
80
57.8
82
58.2
84
58.5
86
58.9
88
59.2
90
59.6
92
60.0
94
60.3
96
60.7
98
61.0
100
61.4
( C)