8-4 Troubleshooting

STATUS Lamp

The STATUS lamp stays lit in green when the server is in successful operation. When the
STATUS lamp is unlit or lit/flashing in amber, it indicates that the server has failed.
The following table lists indications of the STATUS lamp, descriptions, and actions to take.
NOTES:
If the server has the NEC ESMPRO or Off-line Maintenance Utility
installed, you can view the error log to identify the cause of a
trouble.
To cycle power to the server, shut down the server from the OS and
reboot it, if available. If the shutdown from the OS is not available,
reset or execute the forced shut down or disconnect and connect the
power cord to reboot the server.
STATUS lamp
indication
Lit in green
Flashing in
green
Unlit
STATUS lamp
Description
The server is in successful
operation.
The server is in operation with
its memory or CPU degraded.
A single-bit error occurred
frequently.
The server is off-powered.
POST is in progress.
A CPU error occurred.
A CPU thermal error was
detected. (Thermal-Trip)
A watchdog timer has timed out.
An uncorrectable memory error
was detected.
A PCI system error occurred.
A PCI parity error occurred.
A CPU bus error occurred.
Memory dumping is requested.
Action
None
Use the BIOS setup utility, SETUP, to
identify the degraded device and
replace it as soon as possible.
Power on the server.
Wait for a while. The STATUS lamp will
light in a few seconds after POST
completion.
Cycle power to the server. If POST
displays an error message, take a note
on the message and contact your
service representative.
Wait until memory dumping completes.