Gently push the levers to the upright position until they engage the notches in the
DIMM.(3)
10.
Install the components you removed in steps 1 to 5.
11.
Power on the server and verify that POST displays no error messages.
If POST displays an error message, take a note on the message and see the POST error
messages listed in Chapter 8.
12.
Start the SETUP and select [Advanced] → [Memory Configuration] to verify that the
installed DIMM shows the status "Normal". (See Chapter 4 or details.)
13.
Select "Yes" for [Reset Configuration Data] on the [Advanced] menu.
This setting is required to change the hardware configuration data. See Chapter 4 for
details.
14.
If Windows Server 2003 or Windows 2000 is in use, set the paging file size to the
recommended value (total memory size * 1.5) or a greater value. See Chapter 5 for details.
Upgrading Your Server 9-49