4
4-23 Network Setup options
Get Gateway Address Automatically
Yes/No [Yes]
Use this option to get the gateway address automatically for printing with TCP/IP.
This option appears only if you selected DHCP or BOOTP as the protocol in the
previous option.
If you select a DHCP or BOOTP protocol and later change it to RARP, you must
return to Setup and set this option to No. You can then set the address manually.
RARP does not support automatic assignment of the gateway address.
IP Address
[127.0.0.1]
Enter the Fiery IP address for Token Ring. This IP address, unlike an IP address set
automatically, remains the same if you restart the Fiery. You must change the default to
a valid address for your network. For information about setting up printing with
TCP/IP, see
Chapter
Subnet Mask
[255.255.255.0]
This option lets you modify the subnet mask for printing with TCP/IP over Token
Ring. To set the subnet mask, enter one of the following values:
255.0.0.0
255.255.0.0
255.255.255.0
Confirm the subnet mask setting with your network administrator before
N
:
OTE
proceeding. In some cases, the required setting may be different from those listed.
Gateway Address
[127.0.0.1]
This option appears only if you answered No to Get Gateway Address Automatically,
or if you selected RARP as the protocol.
Use this option to set the gateway address for printing with TCP/IP. If your network
uses a gateway, you must change the default to a correct gateway address for your
network.
2.
if the IP address starts with a number less than 128
if the IP address starts with a number from 128 through 191
if the IP address starts with a number greater than 191