HP StorageWorks MSL5000 series User Manual page 87

Tape libraries
Hide thumbs Also See for StorageWorks MSL5000 series:
Table of Contents

Advertisement

Table 7: View SCSI Options (Continued)
Library SCSI Bus ID
Library SCSI Bus Parity
Mail Slot Access
SCSI Mode
Unit Attention
Reporting
Init Element Status
Test Unit Ready
Reporting
Device Capability Page
Length
Transport Element
Base Address
Storage Element
Base Address
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
Option
Lets you set the SCSI addresses for the library robotics. The
default is 0.
Lets you enable or disable the library robotics SCSI bus
parity checking. The default is Enabled.
This option controls access to the mail slot and media
removal. "Prevent Allow" Command Inhibits allows access
to the mail slot via the GUI control panel and allows
media removal. "Prevent Allow" Command Ignored
prevents access to the mail slot and removal of media. This
option is used for some backup applications. The default is
"Prevent Allow" Command Inhibits.
Defines the loader as SCSI-2 or SCSI-3. The default is
SCSI-3.
Lets you select reporting of all or only one stacked-unit
attention conditions. If set to Report All, the unit reports all
unit attention conditions in sequence; if set to Report One,
the unit reports only the highest priority condition. The
default is Report All.
Lets you specify the library's response to the SCSI
INITIALIZE ELEMENT STATUS command. The
possible settings are No Inventory, Force Inventory, and
Force Label Scan. The default is Force Inventory.
Lets you specify the response to a TEST UNIT READY
command if the library is in Sequential Mode. The
possible settings are Standard or Custom. The default is
Custom.
Lets you choose between two lengths of the mode
sense/select device capabilities page (SCSI page 1Fh),
which are Short (14 bytes) and Long (18 bytes), to
accommodate different SCSI device implementations of
this page. The default is Short (14 bytes).
Lets you set the base address for the robotics mechanism.
The default is 0x0.
Lets you set the base address for the magazine slots. The
default is 0x20.
Description
Operation
87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks msl6000 series

Table of Contents