Table 11: Fault Symptom Codes (Continued)
FSC
3200
Shuttle Jammed
(Shuttle could not reach target location.)
3300
Rotary Jammed
(Rotary track could not reach target
location.)
3301
Shuttle on Wrong Side Of The
Rotary
(Zone indicators show that the shuttle is
backwards on the rotary track during
power-up initialization.)
3400
Pass-through Elevator Jammed
(Pass-through shuttle could not reach target
location.)
3500
Vertical Elevator Jammed
(Vertical elevator could not reach target
location. 10U libraries only).
5011
All Slots Empty
(There are no cartridges installed in any of
the reserved cleaning slots.)
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
Message
ERP
Press the Enter button to reboot.
Cycle power to the library or reboot using
the GUI touch screen.
Press the Enter button to reboot.
Cycle power to the library or reboot using
the GUI touch screen.
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
Ensure cartridges are fully inserted in the
magazine(s).
Press the Enter button to reboot.
Cycle power to the library or reboot using
the GUI touch screen.
Press the Enter button to reboot.
Cycle power to the library or reboot using
the GUI touch screen.
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
Check pass-through alignment.
Press the Enter button to reboot.
Cycle power to the library or reboot using
the GUI touch screen.
Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
Press the Enter button to clear the
message.
Insert cleaning cartridge in reserved
cleaning slot.
Invalid user initiated operation. Set
parameters correctly and try again.
Troubleshooting