Troubleshooting
Table 11: Fault Symptom Codes (Continued)
FSC
2081
Move Command Failure
(Move command from or to drive slot
failed. Detected by control task.)
2090
Open Mail Slot Fault
(Door open sensor time-out detected when
open door.)
2091
Open Left Door Fault
(Door open sensor time-out detected when
open door.)
2092
Open Right Door Fault
(Door open sensor time-out detected when
open door.)
2093
Open Doors Fault
(Door open sensor time-out detected when
open door.)
144
Message
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
ERP
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Load/unload a cartridge to the drive to
verify.
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.
Press the Enter button to clear the
message.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Make sure door(s) are closed.