Troubleshooting
Table 11: Fault Symptom Codes (Continued)
FSC
305B
Diag Fetch, Drive not loaded
(Diag: no cartridge present for fetch.)
305D
Diag Timeout waiting for drive
empty, ready
(Fetch, time-out waiting for drive unload.)
305F
Invalid bin number
(Invalid bin number detected in diag.)
3060
Zone Sequence Error
(Robot did not find sensor on power-up.)
3074
Drive 0 Eject Failed
(Eject command time-out.)
152
Message
HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
ERP
Press the Enter button to clear the
message.
Load a cartridge in the drive and retry the
operation.
Invalid user initiated operation. Set
parameters correctly and try again.
Press the Enter button to reboot.
Invalid user initiated operation. Set
parameters correctly and try again.
Ensure the drive shows good status
through the drive status window.
Check the tape cartridge used in the last
operation for damage.
Press the Enter button to clear the
message.
Invalid user initiated operation. Set
parameters correctly and try again.
Cycle power to the library or reboot using
the GUI touch screen. Wait 30 seconds to
power up again.
Press the Enter button to reboot.
Ensure the drive shows good status
through the drive status window.
Deactivate the drive using the GUI control
panel maintenance menu.
Reseat drive.
Load/unload a cartridge to the drive to
verify.
Check the tape cartridge used in the last
operation for damage.
Run the cartridge cycle diagnostic to
verify.