CO600 Changeover Switch

Network Port (RJ45): Connect to the Eucon Network Switch via the RJ-45 cable
provided.
MADI In / Out Ports (96 Combo D): Digital audio in and outs. See the MADI
Hookup
GP Inputs (DA-15): Can be configured using internal jumpers to accept momentary
or closed control inputs.
SNMP Network Port (RJ45): Optional connection for external network.
SNMP Service Port (DE-9): Optional connection for SNMP management.
Power Connectors (IEC): Accepts two standard IEC power cords (provided). Two autorang-
ing switching supplies accept voltages between 100–240 VAC, 50–60 Hz.
CO600 Service Port (DE-9): Optional connection for CO600 management.
SNMP Monitoring (Optional)
The SNMP System Management Controller monitors operating condtions and notifies
the user to take action to avert system failure. It provides a simple way to manage
remote devices and adds a dimension of security to critical applications. The system
management controller is web-enabled and supports mulitple communication protocols.
Figure 3-18 CO600 Changeover Switch
for details on these connections.