SERIAL INTERFACE, CONFIGURATION
FUNCTION
Allows configuration of the IrDA Interface.
FORMAT
<ESC>I2abcde
Place in separate data stream sent to the printer.
EXAMPLE
<ESC>A
<ESC>I2105000
<ESC>Z
OUTPUT
This command does not result in printer output.
NOTES
Use this command with a <ESC>A and <ESC>Z separately. This command cannot be used in
conjunction with other commands.
Settings can be confirmed by performing a test print.
This command becomes valid when the printer is powered on again.
Transmission timeout is only valid for standard and BHT protocols. For protocols other than specified,
this function will be ignored.
Control flow is only valid for IrCOMM protocol. For protocols other than specified, this function will be
ignored.
The default settings are as follows: baud rate, 19200 bps; transmission timeout, 5 seconds;
transmission protocol, standard; flow control, nil.
"i" Programming Reference
Unit 4: Standard Command Codes
a
=
Baud rate
1: 9600 bps
2: 19200 bps
3: 38400 bps
4: 57600 bps
5: 115200 bps
b
=
Parity
0: None
1: Odd
2: Even
c
=
Transmission timeout in seconds
00 to 05: 5
06 to 99: 6 to 99
d
=
Transmission protocol
0: Standard
1: BHT
2: IrCOMM
3: IrOBEX
e
=
Reserved
0: Fixed