2D CODE COMMANDS
PDF417
FUNCTION
Specifies PDF417 of 2D code.
FORMAT
<ESC>2D10aabbcddeeffff<ESC>DNgggg,h...h
Place anywhere after <ESC>V but before <ESC>Q.
EXAMPLE
<ESC>V0100<ESC>H0100
<ESC>2D10,03,09,3,03,18
<ESC>DN0100,0123456789
<ESC>Q2
<ESC>Z
Minimum Module Size: 03 dots wide, 09 dots high
Security Level: 3
Quantity of Data Words per Line: 03
Quantity of Lines per Symbol: 18
OUTPUT
(4-22)
NOTES
If d=e=00, the vertical/horizontal size becomes 1:2 depending on the quantity of specified data. If the
specification of "d" and "e" does not match the data quantity, printing may not properly occur.
When increasing the security level, it is necessary to specify a higher value for "d" and "e".
Module widths set to 01 or 02 may not properly read. Module heights set to 01, 02, or 03 also may not
be properly read.
Sequential numbering is not available and print position is not designable with auto linefeed.
Print of 00H through FFH is definable and registration of format is available.
To improve print quality, increase the minimum module size. To improve the reading ratio, increase the
security level.
The print height may vary when only using alphabet, digits, or alphanumeric characters.
Refer to Appendix: Reference Table 13 for additional information.
"i" Programming Reference
Unit 4: Standard Command Codes
a
= Minimum module width (01 to 09 dots)
b
= Minimum module height (01 to 24 dots)
c
= Security level (0 to 8)
d
= Number of data code words per digit (01 to 30)
00: Automatic (width depnds on data number specified)
e
= Digit number per symbol (03 to 90)
00: Automatic (height depends on data number specified)
f
= Code type
0: Normal
1: Truncated
g
= Data size in bytes (1 to 2681)
h
= Print data
4-33