Scanner Features
❖ Wait Time for Next Original(s): SADF
When dividing originals and scanning them separately with the ADF to form
a single file, select [Set Wait Time] or [Continuous Wait] for the waiting status.
The default setting is Set Wait Time.
The default setting time is 60 sec..
This setting is valid if [SADF] is specified for [Original Feed Type] when scan-
ning.
If [Set Wait Time] is selected, enter the wait time in seconds (3-999) for placing
additional originals with the number keys. Scanning will start automatically
if additional originals are placed within this time. You can end scanning and
begin transmission by pressing the {q} key within this time. Once the spec-
ified time has elapsed, transmission starts automatically.
If [Continuous Wait] is selected, the machine will wait for the additional origi-
nals until the {q} key is pressed. Scanning will start when additional origi-
nals are placed and the {Start} key is pressed. You can end scanning and begin
sending by pressing the {q} key.
Even if originals are placed on the exposure glass, the machine will operate
according to the specified settings. However, every time originals are placed
on the exposure glass, you must press the {Start} key to start scanning.
If a paper misfeed occurs or any of the following operations are performed
while the machine is waiting for additional originals, the countdown stops
6
and does not start again until the {q} key is pressed.
• Changing the settings such as the scan settings
• Opening the upper cover of the ADF
• Pressing the {Interrupt} key to activate the copy mode
❖ Original Setting
Set the default for whether originals are one-sided or two-sided and if two-
sided, the relationship between those sides. When the originals are always the
same, set this for the default to make operation easier. You can select [1 Sided
Original], [2 Sided Orig.: T to T] (Top to Top), or [2 Sided Orig.: T to B] (Top to Bot-
tom).
The default setting is 1 Sided Original.
❖ Switch to Batch
Select [SADF] or [Batch] as the scanning mode that appears as [Original Feed
Type] in the initial display of the scanner mode.
The default setting is SADF.
❖ Mixed Original Sizes Priority
This setting determines whether the original size is to be automatically detected
when originals of different sizes are inserted in the ADF. You can select [On] or
[Off].
The default setting is Off.
If the original size is specified when scanning, this setting is ignored.
When [Off] is selected and [Auto Detect] is selected for scan size, if originals of
different sizes are placed in the ADF, the maximum size will be detected as
the scan size.