Analog Signal Calibration Settings

The functions in the following table
configure the signals for the analog
input
terminals.
settings
do
current/voltage
characteristics – only the zero and
span (scaling) of the signals.
Func.
Name /
Code
SRW Display
C081
O input span calibration
O-ADJ
C082
OI input span calibration
OI-ADJ
C086
AM offset calibration
AM OFFST
NOTE: When you restore factory default settings, the values will change to those listed
above. Be sure to manually reconfigure the values for your application, if needed, after
restoring factory defaults.
Note
that
these
not
change
the
or
sink/source
"C" Function
Scale factor between the external
frequency command on terminals
L–O (voltage input) and the
frequency output,
range is 0.0 to 200%
0100.0%
Scale factor between the external
frequency command on terminals
L–OI (voltage input) and the
frequency output,
0100.0%
range is 0.0 to 200%
Offset adjustment of AM output.
Range is 0.0 to 10.0
Adjust together with B080 (AM
gain adjustment)
0000.0V
- See
page 3-40, 4-55
Freq setpoint
Max. freq
200%
Max. freq /2
0
0V, 4mA
Description
for details.
3 61
3 61
100%
50%
5V, 12mA
10V, 20mA
Run
Defaults
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
100.0 100.0
%
100.0 100.0
%
0.0
0.0
V