3 56
3 56
Analog Function Summary Table – This table shows both functions for the analog
voltage output [AM] terminal, configured by C028. More information on using and
calibrating the [AM] output terminal is in
Option
Code
00
Analog Frequency
Monitor
01
Analog Current
Output Monitor
Analog Function Summary Table
Function Name
Inverter output frequency.
Motor current (% of maximum rated output
current)
"Analog Output Operation" on page
Description
4-55.
Range
0 to max.
frequency in Hz
0 to 200%