Configure Ports - HP Surestore 64 - Director Switch User Manual

Product manager
Hide thumbs Also See for Surestore 64 - Director Switch:
Table of Contents

Advertisement

Configure Ports

Use the procedures in this section to configure names, blocked and unblocked state, 10-100
km extended distance buffering, enable or disable link incident (LIN) alerts for ports, port
type, WWN binding, and the WWN binding name.
Port configuration data is stored in NV-RAM on the switch. Configure data in the following
columns of the Configure Ports dialog box:
Port #
You cannot edit this field. This column identifies the port number. The port numbers
range from 0 through 63.
Name
Enter a name for the port. The port names display in the Port Properties dialog box and
elsewhere in the Product Manager to identify the port.
To identify port numbers for which you want to provide names, place the cursor over
the ports in the Hardware View. As you move over a port, a message displays that
identifies the slot number where the port is installed.
Blocked
Placing a check mark in the check boxes of this column blocks the operation of the
port.
10-100Km
This column is for extended distance buffering. You can enable extended distance for a
port even if it is not an extended distance port. However, enabling extended distance
buffering on a port disables the ability for the port to send broadcast traffic. When you
select this option, the port can support up to 60 BB_Credits to handle link distances up
to 100 km. This enables the port to process 2K frames from attached devices. If this
option is not enabled, the port uses the BB_Credit (1-60) configured through the
Operating Parameters dialog box.
Configure Ports
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore fc-64 director

Table of Contents