L
Message
Link dropped.
Log is currently in use.
Loopback plug(s) must be
installed on ports being
diagnosed. Press Next to
continue.
M
Message
Maximum number of versions
already installed.
N
Message
No file was selected.
No firmware version file was
selected.
No firmware versions to delete.
Cause/Solution
Connection between HP EFC Server and the director has been
lost. Wait for the connection to re-establish. Link re-connects are
attempted every 30 seconds.
Log is in use by another Product Manager. Retry the operation
later.
External loopback diagnostics require an optical loopback plug
to be installed. Ensure that an optical loopback plug is installed
in port optical transceiver before running external wrap
diagnostic testing.
Cause/Solution
The maximum number of firmware versions (8) has been
reached. Delete a firmware version before adding a new
firmware version.
Cause/Solution
Action requires you to select a file.Select a file.
A file was not selected in the Firmware Library dialog box before
an action, such as modify or send was performed. Ensure that
an optical loopback plug is installed in port optical transceiver
before running external wrap diagnostic testing.
There are no firmware versions in the firmware library to delete.
N/A. An informational message.
Appendix
187