Machine Errors - Duerkopp Adler 530 Operating Instructions Manual

Cnc automat for button sewing
Table of Contents

Advertisement

8.6.3

Machine errors

Error
Description
code
1051
Sewing motor timeout
1052
Sewing motor
overcurrent
1053
Sewing motor
overvoltage
1055
Sewing motor
overload
1056
Sewing motor
overheated
1058
Motor speed
1059
(inverted)
1062
Sewing motor IDMA
autoincrement
1302
Sewing motor power
source error
1342
Sewing motor error
-
1344
2101
Step motor X-axis
timeout referencing
2152
Step motor X-axis
overcurrent
2153
Step motor X-axis
overcurrent
2156
Step motor X-axis
overheated
2162
Step motor Y-axis
IDMA autoincrement
1
Serial numbers 0302-00101 ... 0307-00643: the control unit should be used with an Axx.x-Version
Serial numbers 0307-00644 and higher:
Possible causes
· Cable to motor faulty
· Reference switch faulty
. Sewing motor faulty
. Mechanics rough-running
· Cable to motor faulty
· Sewing motor faulty
· Control faulty
. Software not compatible to the
control unit version (A/Bxx.x)
- Mains voltage too high
· Sewing motor is blocked /
rough running
· Sewing motor faulty
· Control faulty
· Sewing motor rough running
· Sewing motor faulty
· Control faulty
Sewing motor faulty
Breakdown
-Plug for sewing motor
not plugged in
-Plug for incremental
sensor not plugged in
Internal error
· Cable to reference switch faulty
· Reference switch faulty
. Step motor faulty
. Mechanics rough-running
· Step motor X-axis faulty
· Control faulty
Mains voltage too high
· Step motor X-axis
rough running
· Step motor X-axis faulty
· Control faulty
Breakdown
the control unit should be used with an Bxx.x-Version
Troubleshooting
· Check cable
· Check reference switch
. Check sewing motor
. Check mechanics
· Check cable
· Check sewing motor
· Check control
. Check the serial number of the
1
DAC III control unit
, if necessary
load the correct software version.
- Check mains voltage
· Remove cause of block / rough
running
· Check sewing motor
· Check control
· Remove cause of rough running
· Check sewing motor
· Check control
Check sewing motor
Switch machine off and on again
- Connect the plug for the sewing
motor
- Connect the plug for the
incremental sensor
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
· Check cable
· Check reference switch
. Check step motor
. Check mechanics
· Check step motor X -axis
· Check control
Check mains voltage
· Remove cause of rough running
· Check step motor X -axis
· Check control
Switch machine off and on again
1
81

Advertisement

Table of Contents
loading

Table of Contents