Machine Selection - Duerkopp Adler DACeco M-TYPE Operating Manua

Table of Contents

Advertisement

7.5

Machine selection

If the programming level of a parameter is selected, buttons S1 and S2 have the following functions:
Acception - Keep S1 (OK) pressed (> one second)
Cancellation - Keep S2 ( ESC) pressed (> one second)
Plus - Briefly press S1 (+) (< one second)
Minus - Briefly press S2 (-) (< one second)
Select the next parameter set by briefly pressing S1. Select the previous parameter set by briefly pressing S2.
The set value is then indicated by the flashing LEDs.
LED1 : 10s digit
LED1 : 1s digit
The LEDs flash every 0.5 seconds. After a pause of 1.5 seconds, the sequence is repeated until it is confirmed or
cancelled.
Confirm the programmed result by pressing S1. Leave the programming level by pressing S2.
The following machine classes can selected:
machine class
1.
669-180010-M
2.
867-1900x0-M
3.
867-2900x0-M
4.
868-x900x0-M
5.
869-x800x0-M
6.
887-160040-M
7.
888-160020-M
You can change the selection with the upper and lower buttons.
The actual selected class will be shown by flashing of the LEDs.
Example select class 867– 1900x0-M:
Push 2 times the upper button.
The lower LED will flash 2 times and after this it has got a longer break. The cycle will be repeated.
Example select class 887-160140-M:
Push 7 times the upper button.
The lower LED will flash 7 times and after this it has got a longer break. The cycle will be repeated.
To accept the selection push and hold the upper button for approx. 2 sec.
Now the parameters will be loaded and you can see it by flashing of the Message LED and you can hear a signal.
If the Message LED is flashing in a constant cycle and you can't hear any signal you can switch off the control.
© 2013 Dürkopp Adler AG
delivery speed
2800
3000
3000
2500
2800
2000
1700
maximum speed
3000
3400
3000
2500
2800
2000
3000
21
Setting the basic functions
0791 100632 EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents