Duerkopp Adler 530 Operating Instructions Manual page 85

Cnc automat for button sewing
Table of Contents

Advertisement

Error
Description
code
3301
Error control
3320
procedure / Test
-
procedure /Step motor
3322
test procedure /
3330
Starting procedure /
-
Sewing procedure /
3332
Winding procedure /
3340
Adjusting aids
3341
3350
-
3351
3353
3360
3361
3400
3401
3403
3358
Sewing procedure:
Handwheel turned
during interruption
3500
Error command
-
interpreter/ motor
3506
synchronization
3520
-
3530
3540
3545
3721
3722
4301
Dongle missing
4302
Dongle empty
4304
Wrong dongle type
4307
Wrong machine class
4311
Error Format-ID
4312
Unknown dongle type
4530
Error menu system /
-
User log-in
4537
4900
5101
NV-RAM empty
5104
NV-RAM
Error check sum
Possible causes
Internal error
Handwheel turned manually
during sewing interruption
Internal error
No dongle plugged in
No data saved on the dongle
The dongle has not the proper
format for the wished function
The dongle data is not
formatted for the cl. 530
Dongle not formatted
properly
Dongle faulty
Dongle not formatted
properly
Dongle faulty
Internal error
Control is brand new, no data
found
Control is for another class,
incompatible data
· NV-SRAM faulty
· Breakdown
Troubleshooting
- Switch the sewing machine off
and on again
- Software update
- Contact the DA-Service staff
Cancel the sewing procedure:
Step the pedal backwards
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
Connect the dongle to the control
Save the data on the dongle
- Use other dongle type
- Format dongle
- Use other dongle type
- Format dongle
- Format the dongle anew
- Use a new dongle
- Format the dongle anew
- Use a new dongle
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
Data will be reset to factory setting.
· Check through Multitest, if
necessary replace control
· Switch machine off and on again
Data will be set back to factory
setting
1
83

Advertisement

Table of Contents
loading

Table of Contents