Description
code
2201
Step motor Y-axis
timeout referencing
2252
Step motor Y-axis
overcurrent
2253
Step motor Y-axis
overcurrent
2256
Step motor Y-axis
overheated
2262
Step motor Y-Axis
IDMA Autoincrement
2911
Step motor error
-
2914
3100
Machine voltage
control
3101
Machine power
voltage
3102
Machine
voltage error
intermediate circuit
sewing motor
3103
Machine
intermediate circuit
step motor
3107
Machine
temperature
3215
Machine hook thread
counter zero
* Those fuses could also be faulty when the control unit does not react and/or powering up does nothing!
82
Possible causes
· Cable to reference switch
faulty
· Reference switch faulty
. Step motor faulty
. Mechanics rough-running
· Step motor Y-axis faulty
· Control faulty
Too high mains voltage
· Step motor Y-axis
rough running
· Step motor Y-axis faulty
· Control faulty
Breakdown
Internal error
Temporary mains voltage
drop
Fuse F403 faulty
Temporary mains voltage
drop
Fuse F402 faulty
Temporary mains voltage
drop
Fuses F400/F404 faulty
(ext.)*
Temporary mains voltage
drop
Fuse F401 faulty
· Vent holes blocked
· Ventilation grid soiled
The counter for the hook
thread counter is zero : the
bobbin is empty
Troubleshooting
· Check cable
· Check reference switch
. Check step motor
. Check mechanics
· Check step motor Y-axis
· Check control
Check mains voltage
· Remove cause of rough running
· Check step motor Y-axis·
· Check control
Switch the sewing machine off
and on again
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
Check mains voltage
Replace fuse F403
Check mains voltage
Replace fuse F402
Check mains voltage
Replace fuses F400/F404 (ext.)
Check mains voltage
Replace fuse F401
· Check the vent holes
· Clean the ventilation grid
Confirm the message and replace
the bobbin.