Technician's Addendum
Maintenance Error Codes ( continued )
Error Code
7803
7804
7805
7806
7807
7808
7809
780A
780C
116
Description
NO PORT BOARDS
AVAILABLE:
Modules not present.
INVALID SANITY RESPONSE:
Sanity test received invalid
responses; applies only to
modules with extension
jacks.
INVALID SLOT NUMBER:
Rare; software could not
process an event detection
because slot number was
invalid.
NOT IN STANDBY MODE:
Reported during cold start or
background check.
SELF TEST NOT
COMPLETED:
Reported during cold start.
TEST RESULT REGISTER BAD:
A module or processor error
during test run.
TEST STATUS REGISTER BAD:
A module or processor error
during test run.
DPR TEST NOT
COMPLETED:
Reported during cold start.
RAM TEST FAILURE:
Memory failed RAM test;
turns on processor LED.
Action
None; delete entry from
transient log.
Reset board. If problem
persists, check module.
None; if problem persists,
restart system.
Reset board. If problem
persists, check module.
Reset board. If problem
persists, check module.
Reset board. If problem
persists, check module.
Reset board. If problem
persists, check module.
If problem persists, check
module.
If problem persists,
replace processor.
Need help?