Lucent Technologies MERLIN LEGEND Release 5.0 Pocket Reference page 115

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

Maintenance Error Codes ( continued )
Error Code
6C05
6C06
6C07
6C08
6C09
6C0A
Description
DS1 LOSS OF MULTIFRAME:
Service on link has been
lost.
DS1 REMOTE MULTIFRAME:
Far end of network interface
is experiencing loss of
multiframe; service on link
has been lost.
DS1 MAJOR ALARM:
Average bit error rate
exceeds 10E-3; service on
link has been lost.
DS1 MINOR ALARM:
Average bit error rate
exceeds 10E-6.
DS1 MISFRAME ALARM:
Misframe count reached 18.
DS1 SLIP ALARM:
Slip count reached 88.
Technician's Addendum
Action
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Maintenance Slot
Error Events
Current hr
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Maintenance Slot
Error Events
Current hr
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Maintenance Slot
Error Events
Current hr
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Maintenance Slot
Error Events
Current hr
111

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MERLIN LEGEND Release 5.0 and is the answer not in the manual?

Table of Contents