Maintenance Error Codes ( continued )
Error Code
0016
0017
0018
0019
0401
0402
0403
0404
Description
POWER UP COLD START:
Module dual port RAM
failure; system programming
OK.
REAL TIME CLOCK FAULT:
Date and/or time incorrect or
unreadable.
RTC COLD START:
This error is not displayed.
RESET TIME & DATE:
System cold-starts because
real-time clock chip is not
working correctly.
ABK CARD NOT INSERTED:
PCMCIA memory card for
translation is not inserted.
ABK INCORRECT CARD
TYPE:
PCMCIA memory card for
non-translation is inserted.
ABK CARD WRITE-
PROTECTED:
Translation card has write-
protected switch on.
ABK EXTENSION BUSY:
A station is in program,
administration, or
maintenance mode.
Technician's Addendum
Action
If problem persists, check
module for slot indicated.
If problem persists,
replace processor
module.
If problem persists,
replace processor
module.
Insert a translation card
or an unformatted card.
Remove current card and
insert a translation card
or an unformatted card.
Turn write-protection
switch to off. If problem
persists, try another card.
If still not working,
replace processor
module.
Wait until station changes
mode.
107