Lucent Technologies MERLIN LEGEND Release 5.0 Pocket Reference page 114

Communications system
Hide thumbs Also See for MERLIN LEGEND Release 5.0:
Table of Contents

Advertisement

Technician's Addendum
Maintenance Error Codes ( continued )
Error Code
3001
4401
4402
5801
6C01
6C02
6C03
6C04
110
Description
ALARM TABLE FULL:
Error logs are full; turns on
processor LED.
USER REQUESTED SYS
ERASE:
Logged after System Erase.
If System Erase is
successful, this error is
removed immediately.
USER REQST
UPGRD/INSTALL:
See error code 0801
DS1 LOSS OF SIGNAL
ALARM:
Service on link has been
lost.
DS1 BLUE ALARM:
All 1s being received;
service on link has been
lost.
DS1 RED ALARM:
Invalid framing information
on incoming signal; service
on link has been lost.
DS1 YELLOW ALARM:
Far end of network interface
has lost frame synchroniza-
tion; service on link has
been lost.
Action
Correct indicated errors,
and then remove entries
from the transient system
error log. If problem
persists, cold-start the
system.
SysProgram System
Restart
If error remains in
transient log, repeat
System Erase. If problem
persists, check
processor.
None.
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.
Usually no action. Check
T1 facility. If problem
persists, contact NSAC
Tier III.