Maintenance Error Codes

Error Code
0001
0002
0003
0004
0005
0006
0007
0008
0009
Description
TIMEOUT COLD START:
System programming OK.
POWER UP WARM START:
System programming OK.
SOFTWARE COLD START:
System programming OK.
SOFTWARE WARM START:
System programming OK.
Reset - DIAGNOSTIC SWITCH:
INCOMPLETE COLD START:
System cold-started while
restart in progress.
SANITY TIMEOUT RESET:
Faulty software, module,
carrier, or processor sanity
timer.
MAX RESET COUNT
EXCEEDED :
System cold-started
because of too many warm
starts.
FRIGID START:
System restarted and
initialized to defaults;
also logged after System
Erase.
Technician's Addendum
Action
No action required;
however, if problem
persists, troubleshoot the
processor.
No action required;
however, if problem
persists, troubleshoot the
processor.
If problem persists,
troubleshoot the
processor.
If problem persists,
troubleshoot the
processor.
If problem persists,
troubleshoot the
processor.
Check module and/or
processor.
If problem persists,
troubleshoot the
processor.
If processor was
removed while in use,
system may perform
frigid start because of
loss of system
programming. Restore
system as described in
System Programming
and Maintenance (SPM) .