Technician's Addendum
Maintenance Error Codes ( continued )
Error Code
000A
000B
000C
000D
000E
000F
0010
0011
0012
0013
0014
0015
106
Description
POWER UP COLD START:
RAM failure in processor;
system programming OK.
CARD
INSERTED/REMOVED:
SLOT STREAM CNT
EXCEEDED :
Slot generated excessive
interrupts.
FMWR NOT IN STANDBY
MODE:
Module firmware not in
standby mode.
COMMAND BUFFER FULL:
TASK RUNNING TOO LONG
INVALID SLOT INTERRUPT:
Cannot determine module
responsible for interrupt.
STACK OVERFLOW:
Processor problem.
INVALID RESET FLAG:
Processor problem.
DUART STREAMING INT:
Processor problem.
PROCESSOR ERR
INTERRUPT:
Processor problem.
MODULE MISMATCH:
Module inserted into wrong
slot.
Action
If problem persists, check
processor.
None.
If problem persists, check
module.
If problem persists, check
module.
If problem persists, check
processor and module.
None; if problem persists,
check processor.
Check modules and
replace if necessary; if
problem persists, check
processor.
Check processor.
Check processor.
Check processor.
Check processor.
Change system
programming for proper
module or install proper
module.