Technician's Addendum
Maintenance Error Codes ( continued )
Error Code
6C0B
6C0C
6C0D
6C0E
6C0F
6C10
6C11
112
Description
HARDWARE INOPERATIVE:
Hardware not operating
properly. If this is the only
100D module or 800 NI-BRI
module, or if this is the
designated clock module, its
TDM bus clock generator
was not activated.
BRI LOSS OF SYNC:
Service on link has been
lost.
BRI NET DEACTIVATED:
BRI NET INV 2B+D LB ACT:
BRI NET INV B1 LB ACT:
BRI NET INV B2 LB ACT:
BRI NET INV IL LB ACT:
Action
A Busy-Out/Restore or
Reset/Restore may clear
problem. If problem
persists, contact NSAC
Tier III.
Usually none; check BRI
facility. If problem
persists, contact NSAC
Tier III.
Usually none; check BRI
facility. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Usually none; link should
return to normal once test
is completed. If problem
persists, contact NSAC
Tier III.
Need help?
Do you have a question about the MERLIN LEGEND Release 5.0 and is the answer not in the manual?