Technician's Addendum
Maintenance Error Codes ( continued )
Error Code
0405
0801
and
1C07
and
5801
0C01
0C02
1C01
108
Description
ABK FAULTY CARD:
Unknown cause of a bad
card.
CTI LINK DELETED:
A board renumber or slot
restore moved the CTI link
to an unacceptable port and
the system has removed the
link.
NO I-VMS PORT IN SERV:
VMS machine may be down.
DID INTERDIGIT TIMEOUT:
Noisy line or CO problem.
POOL M-BUSY EXCEEDS
50%:
More than half the trunks in
pool are busy.
Action
Reset card and retry. If
problem persists, try
another card. If still not
working, replace
processor module.
Check that the following
are true:
1. The system is in
Hybrid/PBX mode.
2. The link is on an 008
MLX or 408 MLX board.
3. The MLX board
firmware vintage is not
29.
4. The extension is not an
operator position.
5. An MLX telephone is
not connected to that
port.
6. Board renumber has
not moved the MLX
extension to the system
programming port.
None
None; if problem persists,
check DID line and inform
CO if necessary.
Check trunk.
Need help?