DWS-3160 Series Gigabit Ethernet Unified Switch Web UI Reference Guide
The fields that can be configured are described below:
Parameter
MEP Name
MEP ID (1-8191)
MD Name
MD Index
MA Name
MA Index
MAC Address
TTL (2-255)
PDU Priority
Click the Apply button to accept the changes made.
Click the Find button to locate a specific entry based on the information entered.
Click the Delete button to remove the specific entry based on the information entered.
Click the Delete All button to remove all the entries listed.

CFM Packet Counter

This window is used to show the CFM packet's RX/TX counters.
To view this window, click OAM > CFM > CFM Packet Counter, as shown below:
Figure 13-13 CFM Linktrace Settings Window
Description
Select and enter the Maintenance End Point name used.
Select and enter the Maintenance End Point ID used.
Select and enter the Maintenance Domain name used.
Select and enter the Maintenance Domain index used.
Select and enter the Maintenance Association name used.
Select and enter the Maintenance Association index used.
Here the user can enter the destination MAC address.
Link-trace message TTL value. The default value is 64.
The 802.1p priority to be set in the transmitted LTM. If not specified, it uses the same
priority as CCMs sent by the MA.