100 Series - HP ProLiant series Troubleshooting Manual

Hide thumbs Also See for ProLiant series:
Table of Contents

Advertisement

Pressing 2 exits the configuration.
Pressing 1 starts the configuration. The following message appears
Attempting to enable OBDR for the attached USB tape drive...
Observe the configuration progress. The following error may appear:
2.
Error - USB tape drive not in Disaster Recovery mode.
Follow the onscreen directions:
3.
Remove power to USB drive and reboot.
The following message should appear:
OBDR is now enabled for the attached USB tape drive.
WARNING: A Type 2 Header PCI Device Has Been Detected...
The BIOS will not configure this card.
It must be configured properly by the OS or driver.
Audible Beeps: 2 short
Possible Cause: Only Type 0 and Type 1 Header PCI Devices are configured by the system ROM. The
device will not work unless the OS or device driver properly configure the card. Typically this message
only occurs when PCI cards with a PCI to PCMCIA bridge are installed.
Action: Refer to the operating system documentation or the device driver information that ships with the
Type 2 PCI device.
WARNING: ProLiant Demand Based Power Management cannot be supported with the
following processor configuration. The system will run in Full Performance mode.
Audible Beeps: None
Possible Cause: The system is configured for HP Static Low mode and the current processor cannot
support this mode.
Action: For more information about the Power Regulator for ProLiant option, refer to the HP ROM-Based
Setup Utility User Guide on the Documentation CD or the HP website
(http://www.hp.com/servers/smartstart).

100 Series

101-I/O ROM Error
Audible Beeps: None
Possible Cause: Options ROM on a PCI, PCI-X, or PCI Express device is corrupt.
Action: If the device is removable, remove the device and verify that the message disappears. Update
Option ROM for a failed device.
102-System Board Failure
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION: Only authorized technicians trained by HP should attempt to remove the system board. If you
believe the system board requires replacement, contact HP Technical Support before proceeding.
Action: Replace the system board. Run the server setup utility.
Error messages 91