Table 40. Intel ® Server Board X38Ml Integrated Bmc Sensors - Intel X38ML - Server Board Motherboard Technical Manual

Technical product specification
Hide thumbs Also See for X38ML - Server Board Motherboard:
Table of Contents

Advertisement

Intel® Server Board X38ML
Default Hysteresis
Hysteresis setting applies to all thresholds of the sensor. This column provides the count of hysteresis for the sensor, which
can be 1 or 2 (positive or negative Hysteresis).
Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the behavior of the Front Panel Status
LED. Refer to Table 31 for more information.
Standby
Some sensors operate on standby power. These sensors may be accessed and/or generate events when the main (system)
power is off, but AC power is present.
Sensor Names
Sensor #
Power Unit
01h
IPMI Watchdog
02h
Physical
03h
Security
BB Ambient
04h
Temp
Revision 1.3
®
Table 40. Intel
Server Board X38ML Integrated BMC Sensors
Sensor Type
Event/
Event Offset
Reading Type
Triggers
Power Unit
Sensor
Power down
Specific
09h
A/C lost
6Fh
Soft power
control failure
Watchdog
Sensor
Timer expired
2
Specific
Hard reset
23h
6Fh
Power down
Power cycle
Timer interrupt
Physical
Sensor
Chassis
Security
Specific
intrusion
05h
6Fh
Temperatu
Threshold
[u,l] [c,nc]
re
01h
01h
Intel order number E15331-006
Contrib.
Assert/
Readable
To
De-assert
Value/Offsets
System
Status
OK
As and De
N/A
Fatal
OK
As
N/A
OK
As and De
N/A
nc =
As and De
Analog
Degra
ded
c =
Non-
fatal
Platform Management
Event
Rearm
Stand-by
Data
Trig
A
X
Offse
t
N/A
Trig
A
X
Offse
t
Trig
A
X
Offse
t
R, T
A
X
79

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the X38ML - Server Board Motherboard and is the answer not in the manual?