Intel STL2 - Server Board Motherboard Quick Start Manual

Quick start guide
Hide thumbs Also See for STL2 - Server Board Motherboard:

Advertisement

A guide for technically qualified persons
Intel
Server Board STL2
®
Quick Start Guide
..................................................................... 2
Installation Process Quick Reference ........................................... 4
Common Problems ....................................................................... 5
Server Board Components............................................................ 6
Back Panel Connectors................................................................. 7
Jumpers ........................................................................................ 8
Installing Processors.................................................................... 10
Install the Processor Terminator .................................................. 15
Install the Voltage Regulator Module.......................................... 16
Memory ....................................................................................... 17
Install the I/O Shield.................................................................... 18
Rearrange the Standoffs............................................................... 19
Install the Server Board Bumpers................................................ 20
Install the Server Board ............................................................... 21
Connect Cables............................................................................ 22
Finish Setting up Your Chassis.................................................... 23
................................................................................ 24
Translations of this guide are available at:
Übersetzungen dieses Handbuchs sind erhältlich bei:
Versiones traducidas de esta guía se encuentran disponibles en:
Des traductions de ce guide sont disponibles à l'adresse:
Le versioni tradotte di questa Guida sono disponibili presso:
As traduções deste guia estão disponíveis em:
http://support.intel.com/support/motherboards/server/STL2/manual.htm
Copyright © 2000 Intel Corporation. All rights reserved. No part of this document may be
copied, or reproduced in any form, or by any means without prior written consent of Intel.
Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including,
but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
Intel assumes no responsibility for any errors that may appear in this document. Intel makes
no commitment to update nor to keep current the information contained in this document.
Third-party brands and trademarks are the property of their respective owners.
Order Number: A28574-001

Advertisement

Table of Contents
loading

Summary of Contents for Intel STL2 - Server Board Motherboard

  • Page 1: Table Of Contents

    Copyright © 2000 Intel Corporation. All rights reserved. No part of this document may be copied, or reproduced in any form, or by any means without prior written consent of Intel. Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
  • Page 2: Before You Begin

    Emissions Disclaimer To ensure EMC compliance with your local regional rules and regulations, the final configuration of your end system product may require additional EMC compliance testing. For more information please contact your local Intel Representative. ® See the Intel Server Board STL2 Product Guide for product Safety and EMC regulatory compliance information.
  • Page 3 Windows 98 / Windows 2000 and use Adobe Acrobat Safety and Regulatory Compliance See the Intel Server Board STL2 Product Guide for product Safety and EMC regulatory compliance information. Intended uses: This product was evaluated for use in servers that will be installed in offices, computer rooms, and similar locations.
  • Page 4: Installation Notes

    This guide Install the server board bumpers This guide Install the server board This guide Connect cables to the server board This guide and the chassis manual Finish setting up your chassis Chassis manual Intel Server Board STL2 Quick Start Guide...
  • Page 5: Common Problems

    WOL. If the standby current is not present, your board will not boot. The system sometimes works, but is exhibiting erratic behavior. This is typically the result of using a under-powered power supply. Make sure it’s at least a 300 W power supply. Intel Server Board STL2 Quick Start Guide...
  • Page 6: Server Board Components

    System fan connector FAN1A System fan connector FAN2A (P27) (P11) Front panel connector (P23) I/O ports Speaker connector (P25, four pin) AA. Primary processor heatsink fan Ultra Single Ended (SE) SCSI connector (P12) connector (P9) Intel Server Board STL2 Quick Start Guide...
  • Page 7: Back Panel Connectors

    Back Panel Connectors OM10672 USB connectors Serial port 2 connector Serial port 1 connector NMI switch Parallel port connector Keyboard connector Mouse connector Video connector Network connector Intel Server Board STL2 Quick Start Guide...
  • Page 8: Jumpers

    Jumpers 1J15 OM10683 Configuration Jumper (1J15) Jumper Name Pins What it does at system reset CMOS clear If these pins are jumpered, the CMOS settings will be cleared on the next reset. These pins should not be jumpered for normal operation. Password If these pins are jumpered, the password will be Disable...
  • Page 9: Reserved

    Reserved 9-10 Reserved. These pins should not be jumpered for normal operation. Reserved 11-12 Reserved. These pins should not be jumpered for normal operation. NOTE: Pins 9-11 should be jumpered for normal operation. Intel Server Board STL2 Quick Start Guide...
  • Page 10: Installation Procedures Installing Processors

    Installation Procedures Installing Processors If you are installing only one processor, you must install a terminator in the secondary processor socket. Observe the safety and ESD precautions at the beginning of this document. Raise the locking bar on the socket. OM10686 STL2 Server Board Quick Start Guide...
  • Page 11 Aligning the pins of the processor with the socket, insert the processor into the socket. Note what the processor speed is so you can set the jumpers correctly. OM08879 Close the handle completely. OM08880 Intel Server Board STL2 Quick Start Guide...
  • Page 12 Place the fan heatsink on top of the processor. OM10680 STL2 Server Board Quick Start Guide...
  • Page 13 Then use a screw driver or other tool to attach the remaining side. OM10681 Connect the processor fan cable to the processor fan connector. OM10671 Intel Server Board STL2 Quick Start Guide...
  • Page 14 After you have installed the processor(s), you must configure the speed jumpers. OM10674 CPU Clock Speed (5E1) Pins Pins Pins Pins Pins Pins Speed 9-10 11-12 1000 Repeat for the second processor. The second processor must be the same speed and within one stepping of the primary processor. If you are installing two processors, skip the section titled “Install the Processor Terminator.”...
  • Page 15: Install The Processor Terminator

    If you are installing two processors, skip this section. Raise the locking bar on the socket. Aligning the pins of the processor terminator with the socket, insert the terminator into the socket. Close the handle completely. OM10679 Intel Server Board STL2 Quick Start Guide...
  • Page 16: Install The Voltage Regulator Module

    Install the Voltage Regulator Module If you are installing two processors, you must install a voltage regulator module (VRM). Orient the VRM as shown and press it into the connector. Make sure the plastic latches engage the VRM. OM10677 STL2 Server Board Quick Start Guide...
  • Page 17: Memory

    DIMMs. Slot 1 is the slot farthest from the processors. Installed DIMMs must be the same speed and must all be registered. For a list of supported memory, call your service representative or visit the Intel Support website: http://support.intel.com/support/motherboards/server/STL2/compat.htm...
  • Page 18: Install The I/O Shield

    Install the I/O Shield NOTE An ATX 2.03-compliant I/O shield is provided with the server board. The shield is required by Electromagnetic Interference (EMI) regulations to minimizes EMI. If the shield does not fit the chassis, obtain a properly sized shield from the chassis supplier. The shield fits the rectangular opening near the power supply in the back of the chassis.
  • Page 19: Rearrange The Standoffs

    18, 19. The hole numbers are stamped in the chassis sheet metal. Make sure the two positioning standoffs are in holes 17 and 19. You chassis may be different from the illustration. OM10675 Intel Server Board STL2 Quick Start Guide...
  • Page 20: Install The Server Board Bumpers

    Install the Server Board Bumpers Peel the adhesive backing from two rubber bumpers; stick the bumpers to the chassis wall. 8.250 [209.55] 5.250 [133.35] 5.250 [133.35] OM10676 STL2 Server Board Quick Start Guide...
  • Page 21: Install The Server Board

    Insert the remaining screws through the mounting holes and into the threaded standoffs. Make sure the board is properly seated, then tighten all the screws firmly, starting with the screws in the center of the board. OM10684 Intel Server Board STL2 Quick Start Guide...
  • Page 22: Connect Cables

    P25) on the server board. Connect the main chassis fans (F) to the FAN3A (P29) and FAN2A (P27) fan connectors on the server board. If you are integrating an Intel SC5000 server chassis, you must rotate the bottom chassis fan 180° so the fan cable will reach the connector.
  • Page 23: Finish Setting Up Your Chassis

    You are now ready to install drives into your chassis. We recommend you install drives before connecting their data cables to the server board. We recommend you connect the blue connector on the IDE cable to the server board before you connect the floppy cable. Intel Server Board STL2 Quick Start Guide...
  • Page 24: Getting Help

    World Wide Web http://support.intel.com/support/motherboards/server/STL2 Telephone Talk to a Customer Support Technician* (Intel reserves the right to change pricing for telephone support at any time without notice). In U.S.: 1-900-555-5800 (M–F, 7:00 am –5:00 pm , Th 7:00 am –3:00 pm , PST).