Option
-mp_blade_id <mp#>
-mirror_id <mun#>

Examples

Changing the setting of a journal: 6. Changing the data overflow watch time to 15 seconds.
# raidcom modify journal -journal_id 6 -data_overflow_watch 15
Changing the setting of a journal: 6. Changing the data overflow watch time to 15 seconds.
Changing the timer type to the system clock of the mainframe host.
# raidcom modify journal -journal_id 6 -data_overflow_watch 15 -timer_type system
Changing the setting of Journal: 6. Changing the MP Blade ID of the journal to #2.
# raidcom modify journal -journal_id 6 –mp_blade_id 2
Changing the setting of Journal: 6. Instructing to store journal data in the secondary journal to the
cache.
# raidcom modify journal -journal_id 6 -cache_mode y
Changing the setting of Journal: 6. Change the path block monitoring time of Mirror ID: 1 to 59
minutes.
# raidcom modify journal -journal_id 6 -path_blocked_watch 59 -mirror_id 1

raidcom add ldev

Makes an LDEV to the specified parity group or the external volume group. Or, makes V-VOL for
Thin Provisioning/Smart Tiers/Snapshot to the specified pool.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.

Syntax

raidcom add ldev {-parity_grp_id <gno-sgno>| - external_grp_id <gno-sgno>
| -pool {<pool ID#> | <pool naming> | snap}} -ldev_id <ldev#> -capacity <size> | -offset_capacity <size> |
-cylinder <size> |
[-emulation <emulation type>][-location <lba>][-mp_blade_id <mp#>]
Description
Specifies an MP Blade ID (0-7).
Changing MP Blade ID should be executed during off-peak hours of I/O
loading. Do not change the MP blade ID during initial copying of
Continuous Access Journal (on-peak hours of I/O loading).
To change the MP Blade ID again for the same journal, wait for more than
30 minutes after changing the MP Blade ID.
For example:
-mp 2
Specifies a Mirror ID.
If the setting is omitted, "0" is used.
raidcom add ldev
151