Troubleshooting
Identifying LCD-Indicated Conditions
Table 3-1. Chassis Codes for J5000 and J7000 Workstations
Ostat
Code
FRU
TST
4 n 60
SYS BD
FLT
5 n 00
SYS BD
FLT
5 n 02
SYS BD
FLT
5 n 04
SYS BD
FLT
5 n 07
SYS BD
FLT
5 n 08
SYS BD
FLT
5 n 0A
SYS BD
FLT
5 n 0B
SYS BD
FLT
5 n 0C
SYS BD
INI
7000
DIMM
INI
7002
SYS BD
FLT
7004
SYS BD
FLT
7005
DIMM
TST
7010
DIMM
WRN
7011
DIMM
FLT
7012
DIMM
FLT
7013
DIMM
TST
7016
DIMM
WRN
7017
DIMM
FLT
701F
DIMM
60
Message
CPU n dcache miss
unknown bus err
path err assertd
data parity err
Runway dir error
Runway broad err
illegal response
bus timeout
CPU sync failure
start DIMM scan
init mem tables
mem plt upd fail
insufficient mem
check DIMM order
skip DIMM ord ck
DIMM order error
DIMM order error
DIMM pair check
skip mem pair ck
no memory found
Description
CPU n is starting its data cache miss
self-test.
CPU n detected an unknown error on the
system bus (Runway).
CPU n detected a path error on the
system bus (Runway).
CPU n detected a data, address, or control
parity error on the system bus (Runway).
CPU n detected a directed error on the
system bus (Runway).
CPU n detected a broadcast error on the
system bus (Runway).
CPU n received data that did not match
any outstanding data request.
CPU n timed out before receiving
requested data. The responder is logged in
the system responder address.
CPU n's synchronizer detected a rule
violation on the system bus (Runway).
Start looking for installed DIMMs.
Initialize memory data structures.
Error updating memory platform data.
Insufficient memory detected to continue.
Start memory DIMM order check.
Bypass memory DIMM order check.
Memory DIMMs are not in the proper
order.
Memory DIMMs are not in the proper
order. As a result, the system cannot
access one or more DIMMs and has
deallocated all inaccessible DIMMs.
Start memory DIMM pair check (DIMMs
in a pair (e.g. 0a/0b) must match in
J7000).
Bypass memory DIMM pair check.
Memory scan couldn't find any DIMMs.