Power Server Cabinets On And Off - HP Rx2620-2 - Integrity - 0 MB RAM Manual

Integrity servers with microsoft windows server 2003
Hide thumbs Also See for Rx2620-2 - Integrity - 0 MB RAM:
Table of Contents

Advertisement

2.
Use the fruled command to manage (turn on, off, or blink) the attention indicator for a
system hardware component.
NOTE:
commands (-h and -g for IPMI over LAN connections; -h and -u for WBEM/WMI
connections). For a complete explanation of these options, see the command description in
"nPartition Commands Reference" (page
From the command line you can manage LEDs for the following hardware components:
Cells—Use fruled to blink or turn off a cell attention indicator.
— Turn Off: The fruled -f -c# command turns off the attention indicator for the
— Blink: The fruled -o -c# command blinks the attention indicator for the specified
I/O Chassis—Use fruled to blink or turn off HP Superdome I/O chassis attention
indicators.
Specify the I/O chassis using cabinet/bay/chassis notation (#/#/#).
— Turn Off: The fruled -f -i#/#/# command turns off the attention indicator for
— Blink: The fruled -o -i#/#/# command blinks the attention indicator for the
Cabinet Numbers—Use fruled to blink or not-blink (keep lit) the cabinet number LCD
for an HP Superdome cabinet.
— Not-Blink: The fruled -f -b# command stops blinking (keeps it lit) the cabinet
— Blink: The fruled -o -b# command blinks the cabinet number LED for the

Power server cabinets on and off

When powering off a cabinet, you turn off 48-volt power to the cabinet thus causing all cells and
all I/O chassis to power off, and causing most fans to turn off.
Changes in cabinet power status do not affect the standby power that supplies system utilities
such as the MP and keeps some fans running. These utilities and fans can receive power as long
as standby power is enabled.
CAUTION:
power off and power on cabinet 0 and cabinet 1 in such a way that both cabinets are off for an
overlapping interval.
If either Superdome 64-way cabinet is powered off then powered on while the other cabinet
remains on, then communications between the two cabinets is lost.
CAUTION:
The cabinet power switch and the PE command at the management processor Command menu
do not check whether system hardware is in use before powering it off.
Power on or power off server cabinets using any one of the following procedures:
82
Using Other Tools to Manage nPartitions
You must include the correct remote administration options when issuing par
specified cell (-c#). To turn off all cell attention indicators use the fruled -f -c
command.
cell (-c#).
the specified I/O chassis (-i#/#/#). To turn off all I/O chassis attention indicators
use the fruled -f -i command.
specified I/O chassis (-i#/#/#).
number LCD for the specified cabinet (-b#).
specified cabinet (-b#).
When you power on or off HP Superdome 64-way compute cabinets, you must
Before powering off system hardware, you first must check whether it is being used.
89).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bl860cNpartition

Table of Contents