Table 6-1 nPartition commands messages
Message
Cannot connect.
Unsupported platform.
The nPartition Configuration
Privilege of the target complex is
restricted.
Cannot determine the state of the
nPartition Configuration Privilege.
Cannot determine if the platform
is partitionable.
Cannot write the Stable Complex
Configuration Data.
Cannot write the Partition
Configuration Data.
Unable to update the Stable
Complex Configuration Data.
Cannot lock Stable Complex
Configuration Data.
Unable to read lock for partition.
Cannot lock Partition
Configuration Data.
Cannot lock cell data for cell <n>.
116
Troubleshooting
Cause
1. The nPar Provider you are
attempting to use is not running. If
using the -h option, check your local
management system's nPar provider.
If you are using the -u option, verify
the nPar provider on the remote
target nPartition.2. MP is not
available on the network. 3. MP
settings are incorrect.
1. Command was run on the local
system, which is not a partitionable
server.2. With -u and -h options,
target host is not a partitionable
server.
The MP is set to disallow changes to
the configuration of any nPartition
except the one from which the request
is made.
The command cannot retrieve this
data from the provider. In most cases,
this is caused by excessive lost
packets during data retrieval.
1. See "Unsupported Platform"
above.2. The command cannot
retrieve this data from the provider.
In most cases, this is caused by
excessive lost packets during data
retrieval.
The referenced data is inaccessible or
was left in a locked state. See the AEL
entry for more information.
The referenced data was locked when
the command attempted to access it.
Recommended Action
1. Make sure the nPar Provider
component is installed. On Windows,
verify the nPar provider service is
running using the Start > Control Panel
> Administrative Tools > Services
applet.2. Verify you have network
connectivity by telnetting to the MP and
successfully logging in.3. Telnet to the
MP. Enter Commands Menu and enable
IPMI LAN access with the SA command,
and set an IPMI password with the SO
command.
1. Use the -g and -h options or the -u
and -h options to specify a partitionable
complex as the target of the operation.2.
Specify the hostname or IP address of an
nPartition.
This can only occur when using the -u
option. In that case, specify the nPartition
that will be altered as the target in the -h
option.
Retry the command, or use a
management PC with more reliable
network communications to the MP.
1. See "Unsupported Platform" above.
2. Retry the command or use a
management PC with more reliable
network communications to the MP.
If the data was left locked, use the
parunlock command to unlock it. See
"parunlock" (page
99), or the on-line
help for the parunlock command.
First retry the command. The data is
normally locked only for short periods.
If the data remains locked, use the
parunlock command to unlock it. See
"parunlock" (page
99), or the on-line
help for the parunlock command.