HP Rx2620-2 - Integrity - 0 MB RAM Manual page 103

Integrity servers with microsoft windows server 2003
Hide thumbs Also See for Rx2620-2 - Integrity - 0 MB RAM:
Table of Contents

Advertisement

frupower [-d] -I [-l cabinet] [-l...]
The -h... -g... options must be specified to cause the command to send its management
request using IPMI over LAN to a MP in another server complex (but can also be used as a
"loopback access" to the MP in the local complex).
The -h... -u... set of options must be specified to cause the command to send its
management request using WBEM to an nPartition other than the local nPartition (but can
also be used as a "loopback access" to the local nPartition).
The -g and -u options are mutually exclusive.
Options
Option
-d
-o
-f
-c cell
-i IOchassis
-C
-I
-l cabinet
-u username:[passwd]
-g [passwd]
-h IPaddress|hostname
Example
In the following example, you connect to the server's management processor (MP) from your
management station. The MP IP number is 192.168.24.68, and the MP password is "password".
Since you are connecting remotely using IPMI over LAN, you must include the -h... -g...
options with each command.
You want to view the power status for all cells in the complex. You use the frupower command
(with the -C option).
1.
Open a command window on the management station (Start > Run >entercmd >click OK).
Description
Display power status of the specified cells or I/O chassis. This is the default.
Power on the specified cells or I/O chassis.
The -o and -f options are mutually exclusive. The -o and -f options are unavailable
with -C and -I.
Power off the specified cells or I/O chassis.
The specified cell is powered on/off or the power status is displayed.A cell can be specified
either in the local (cabinet/slot) or global (cell_ID) format.
The specified IOchassis is powered on/off or the power status is displayed.
Display power status of all cells. By default the scope is the entire complex if the -l option
is not specified.
Display power status of all I/O chassis. The scope is the entire complex if the -l option
is not specified.
Limit the scope of the -C or -I option to the specified cabinet.
Specifies the account and authorization to access an nPartition other than the local
nPartition.
The -h option is required if this option is used.
• username specifies a configured user name on the target nPartition.
• passwd specifies the password associated with the username. If this field is empty, the
command prompts for the password.
Allows access to the complex specified by the -h option. The accessed complex is then
considered the target complex. Access is through the MP LAN port.The -h option is
required if this option is used.
passwd specifies the IPMI password of the MP. If this field is omitted, the command
prompts for the password.
This option is only used in combination with either the -u or -g option. IPaddress|hostname
specifies the IP address or hostname of the target nPartition (-u) or MP (-g).
frupower