Brocade Communications Systems A7533A - Brocade 4Gb SAN Switch Base Reference Manual page 161

Brocade fabric os mib reference guide v6.0.0 (53-1000602-01, april 2008)
Hide thumbs Also See for A7533A - Brocade 4Gb SAN Switch Base:
Table of Contents

Advertisement

The values are 1 through the value in swNumSensors.
swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2
The type of sensor.
swSensorStatus 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3
The current status of the sensor.
Values
Possible values are:
For Temperature, valid values include 3 (below-min), 4 (nominal), and 5 (above-max).
For Fan, valid values include 3 (below-min), 4 (nominal), and 6 (absent).
For Power Supply, valid values include 2 (faulty), 4 (nominal), and 6 (absent).
swSensorValue 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4
The current value (reading) of the sensor.
The value -2147483648 represents the maximum value of integer value; it also means that the
sensor does not have the capability to measure the actual value. In v2.0, the temperature sensor
value is in Celsius, the fan value is in RPM (revolutions per minute), and the power supply sensor
reading is unknown.
The unknown value -2147483648 indicates the maximum value of integer value.
swSensorInfo 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5
Additional information on the sensor. It contains the sensor type and number, in textual format; for
example:
SLOT #0: TEMP #3
FAN #1
Power Supply #1
Return values for the Brocade 12000, 24000, and 48000 directors depend upon the configuration
of your system.
Fabric OS MIB Reference
53-1000602-01
1: unknown (1)
2: faulty (2)
3: below-min (3) The sensor value is below the minimal threshold.
4: nominal (4)
5: above-max (5) The sensor value is above the maximum threshold.
6: absent (6) The sensor is missing.
swSensorType 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2
5
143