This OID cannot be used for either firmwareDownload or configDownload (cannot be set and is
readonly) for FOS v4.4 and above. The value displayed is always NULL (zero-length).This is not
supported in FOS v6.0.0.
swFlashDLFile 1.3.6.1.4.1.1588.2.1.1.1.1.15
The name of the file to be downloaded or uploaded.
This OID cannot be used for either firmwareDownload or configDownload (cannot be set and is
readonly) for FOS v4.4 and above. The value displayed is always NULL (zero-length).This is not
supported in FOS v6.0.0.
swFlashDLPassword 1.3.6.1.4.1.1588.2.1.1.1.1.16
The password to be used for FTP transfer of files in the download or upload operation.
This OID cannot be used for either firmwareDownload or configDownload (cannot be set and is
readonly) for FOS v4.4 and above. The value displayed is always NULL (zero-length).This is not
supported in FOS v6.0.0.
swBeaconOperStatus 1.3.6.1.4.1.1588.2.1.1.1.1.18
The current operational status of the switch beacon.
Values
Possible values are:
•
•
swBeaconAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.19
The desired status of the switch beacon.
Values
Possible values are:
•
•
swDiagResult 1.3.6.1.4.1.1588.2.1.1.1.1.20
The result of the power-on startup test (POST) diagnostics.
Values
Possible values are:
•
•
•
Fabric OS MIB Reference
53-1000602-01
on (1) The LEDs on the front panel of the switch run alternately from left to right and right to
left. The color is yellow.
off (2) Each LED is in its regular status, indicating color and state.
on (1) The LEDs on the front panel of the switch run alternately from left to right and right to
left. Set the color to yellow.
off (2) Set each LED to its regular status, indicating color and state.
sw-ok (1) The switch is okay.
sw-faulty (2) The switch has experienced an unknown fault.
sw-embedded-port-fault (3) The switch has experienced an embedded port fault.
swFlashDLFile 1.3.6.1.4.1.1588.2.1.1.1.1.15
5
141